Locating Feet - Metric
Kipp - Leveling Pads
Material:
Plate steel, damper plate PUR elastomere (Sylomer V12)
Surface finish:
Plate blue chromated; damper plate gray, fixed, cannot slip. Range of use from -30 °C to +70 °C
Note:
The manageable load given in the table is a recommendation of the permanent static load up to which the absorption unit should be used.
This static load corresponds to a pressure per area of 0.4 N/mm², at which the material reaches its optimum absorption properties. Here it is taken into account that under dynamic demands an additional load, up to 0.6 N/mm² may occur.
The damper plate absorbs vibrations and prevents slipping of the Locating Foot.
Item # |
IntegrationID |
D |
H |
D2 |
D1 |
Load capacity (under pressure of 0.4 N/mm²) |
H1 (under pressure of 0 / 0.4 / 0.6 N/mm²) |
Max Load |
Stud Length |
---|---|---|---|---|---|---|---|---|---|
M66801 |
IntegrationID
N/A 78153 |
D N/A 36.00 mm | H N/A 15 mm | D2 N/A 5.50 mm | D1 N/A 31.00 mm | Load capacity (under pressure of 0.4 N/mm²) N/A 212 N | H1 (under pressure of 0 / 0.4 / 0.6 N/mm²) N/A 4 / 2.8 / 1.9 mm | Max Load N/A | Stud Length N/A |
M66802 |
IntegrationID
N/A 78154 |
D N/A 46.00 mm | H N/A 17.00 mm | D2 N/A 6.60 mm | D1 N/A 41.00 mm | Load capacity (under pressure of 0.4 N/mm²) N/A 435 N | H1 (under pressure of 0 / 0.4 / 0.6 N/mm²) N/A 4 / 2.8 / 1.9 mm | Max Load N/A | Stud Length N/A |
M66803 |
IntegrationID
N/A 78155 |
D N/A 56.00 mm | H N/A 19 mm | D2 N/A 9.00 mm | D1 N/A 50.00 mm | Load capacity (under pressure of 0.4 N/mm²) N/A 705 N | H1 (under pressure of 0 / 0.4 / 0.6 N/mm²) N/A 4 / 2.8 / 1.9 mm | Max Load N/A | Stud Length N/A |
M66804 |
IntegrationID
N/A 78156 |
D N/A 74.00 mm | H N/A 21.00 mm | D2 N/A 9.00 mm | D1 N/A 68.00 mm | Load capacity (under pressure of 0.4 N/mm²) N/A 1372 N | H1 (under pressure of 0 / 0.4 / 0.6 N/mm²) N/A 4 / 2.8 / 1.9 mm | Max Load N/A | Stud Length N/A |